Some families have very long door openings and need to install some cabinet furniture in them. In order to satisfy the use of the family, the door hole will not be too empty. But before that, it is necessary to determine the size of the door opening and how to measure it. The following small editor will show you. 1. Standard door opening size inner door standard door opening size: 860mm × 2050mm × 240mm entrance door standard door opening size: 950mm × 2050mm × 90mm or 950mm × 2050mm × 220mm decoration company when measuring the room...

Some families have very long door openings and need to install some cabinet furniture in them. In order to satisfy the use of the family, the door hole will not be too empty. But before that, it is necessary to determine the size of the door opening and how to measure it. The following small editor will show you.

木门尺寸知识丨门洞尺寸标准介绍_1

I. Standard door opening size

the size of the standard door opening of inner door is: 860mm × 2050mm × 240mm. The size of the standard door opening of entrance door is: 950mm × 2050mm × 90mm or 950mm × 2050mm × 220mm when the decoration company measures the House, generally, the detailed size of the door opening will be measured appropriately. The measurement method of the door opening size, for the measurement of the door opening, the following door opening is the size of the door opening that has been decorated and will not be modified. For the door hole which is still in the process of decoration, it is suggested to make a door hole with a height of 2050mm and a width of 860mm. According to this size, the display effect of the finished door produced by the door opening is the best. It is ergonomic and aesthetic.

II. How to measure the door opening size

1. If the error exceeds 20mm, the Wall hole should be corrected. The correction can be corrected by cement mortar or lime.

2. Measure the width and height of the door opening. Whether the upper, middle and lower points of the door opening are consistent shall be measured. If they are inconsistent, the narrowest point shall prevail, but the error shall not exceed 20mm.

3. If the error of wall thickness exceeds 5mm, it needs to be corrected.

4. The thickness measurement of the wall of the door opening should also measure the upper, middle and lower parts to see if the thickness of the wall is the same, and at the same time, it also depends on whether the thickness of the left and right wall is the same as that of the wall on the top of the door opening, different take their maximum values, but the error should not exceed 5mm.

5. If the wall is a T-shaped wall, you need to use a thin wood board as a fake wall with a width of 50-60mm to place door casing. The thickness of the wall is the same as that of the wall.

6. The minimum thickness of the door opening wall is not less than 80mm. The strength of the low and 80mm door frame is not very large, and the support for the door is not enough. If it is less than 80mm, the thickness of the wall needs to be thickened to more than 80mm.

The standard installation of electric water heater involves a series of requirements on electricity standard, protection switch, waterway and circuit, so professional personnel must be invited to install it. In order to use it more safely and safely in future life.